VLine by PAL fire doorsets, were designed to solve a number of challenges faced across the industry, from installing to managing fire doors.
Our fire doors satisfy both legislative and commercial requirements through the combination of high-quality sustainable manufacture, competitive lead times and competitive pricing, wrapped up with the unmatched service that is quickly becoming synonymous with PAL in the construction sector.
Here are some indicative costs and lead times on popular specifications to offer an example of how cost-effective these doorsets are.
Packaging: Fully boxed FD30s doorset
Leaf Sizes: 2040x926x54
Overall Frame: 2081x996x80
Architrave: None
Ironmongery fitted: 3 no. Class 13 SSS ball-bearing hinges, peephole, dropseal and GU Multipoint lock with 3* cylinder.
Ironmongery supplied loose: 2-4 face fixed scissor arm closer, chain, numerals and SSS lever handles.
Data Chip: Door is pre-fitted with Door Data Systems pin with certification, warranty and installation instructions pre-loaded.
Security Rating: PAS24:2016
Acoustic Rating: 29dB
FSC: Yes
Packaging: Fully boxed doorset
Leaf Sizes: 2040x926x44
Overall Frame: 2079x992x100
Architrave: Std-64×12, Foil finish
Ironmongery: Recessed and fitted lock and hinges. Finger pull and signage supplied loose.
Data Chip: Door is pre-fitted with Door Data Systems pin with certification, warranty and installation instructions pre-loaded.
FSC: Yes
Please note:
For more information about VLine by PAL Doorsets visit our products page.
For help in selecting the right doorset for your project, our experienced team are on hand to help. Just fill out our contact form or give us a call.
All products hold primary test evidence and are built to last, produced in a traditional fashion of stile and rail with a 100% recycled core and dense sub-faces.
Compliance to British Standards:
BS EN 1634:1 Fire resistance and smoke control tests for door, shutter and, openable window assemblies and elements of building hardware. Fire resistance tests for doors, shutters and openable windows.
BS 476-22 Fire Resistance Test to Building Material – Non-loadbearing elements. BS 476-22 has been prepared under the direction of the Fire Standards Committee, and describes the procedures for determining the fire resistance of non-loadbearing elements of building construction.